AUDIX Network Testing 14-33
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
_ ______________________________________________________________________________________
AUDIX CHANNEL STATUS
(SEE ALSO FIGURE 14-20)
NOTE:
For AUDIX R1V3 or later,
channels 2 and 4 on Generic 1, Generic 3, or System 75
will always be DOWN. Channels 1 and 3 on a
MERLIN II will always be DOWN.
DOWN
(SEE NOTE)
RUN CHANNEL INTERNAL
LOOP-AROUND TEST
(TEST 2)
MAINT : NET FORM
TEST
PASSED
?
NO
YES
CHECK CHANNEL STATUS
(FIG 14-20 and 14-21)
CHECK BOARD
STATUS (FIG 14-19)
EQUIP CHANNEL
SYS : TRA : NET
FORM
BLANK NOT EQUIPPED
RUN LOCAL CONNECTION
TEST (TEST 1)
MAINT : NET FORM
STILL
UNKNOWN
?
NO
YES
CHECK SWITCH AND
AUDIX TRANSLATIONS
REPLACE THE
ACC(E) BOARD
BUSY OUT CHANNEL
(TEST 3)
MAINT : NET FORM
UNKNOWN
Figure 14-21. Checking the ACC(E) Channel Status